Veuillez indiquer votre numéro de commande dans l'e-mail. Nous nous efforçons de répondre à toutes les demandes par e-mail dans un délai d'un jour ouvrable.
In vivo (Ajouter les solvants au produit individuellement et dans l'ordre.)
Homogeneous suspension
CMC-NA
≥5mg/ml
Taking the 1 mL working solution as an example, add 5 mg of this product to 1 ml of CMC-Na solution, mix evenly to obtain a homogeneous suspension with a final concentration of 5 mg/ml.
Clear solution
5%DMSO
40%PEG300
5%Tween80
50%ddH2O
Validé par les laboratoires Selleck. Si vous avez besoin d'ajustements à cette formulation, contactez notre équipe commerciale pour des tests personnalisés.
5mg/ml
(12.23mM)
Taking the 1 mL working solution as an example, add 50 μL of 100 mg/ml clarified DMSO stock solution to 400 μL of PEG300, mix evenly to clarify it; add 50 μL of Tween80 to the above system, mix evenly to clarify; then continue to add 500 μL of ddH2O to adjust the volume to 1 mL. The mixed solution should be used immediately for optimal results.
Clear solution
5% DMSO
95% Corn oil
Validé par les laboratoires Selleck. Si vous avez besoin d'ajustements à cette formulation, contactez notre équipe commerciale pour des tests personnalisés.
2.5mg/ml
(6.11mM)
Taking the 1 mL working solution as an example, add 50 μL of 50 mg/ml clear DMSO stock solution to 950 μL of corn oil and mix evenly. The mixed solution should be used immediately for optimal results.
* <1 mg/ml signifie légèrement soluble ou insoluble. * Veuillez noter que Selleck teste la solubilité de tous les composés en interne, et la solubilité réelle peut différer légèrement des valeurs publiées. Ceci est normal et est dû à de légères variations d'un lot à l'autre. * Expédition à température ambiante (les tests de stabilité montrent que ce produit peut être expédié sans aucune mesure de refroidissement.)
Préparation des solutions mères
Activité biologique
Description
CCG-203971 est un nouvel inhibiteur de petite molécule de la voie Rho/MRTF/SRF avec une valeur IC50 de 0,64 μM pour SRE.L. Il inhibe la transcription génique médiatisée par Rho.
Cibles
Rho
SRE.L
0.64 μM
In vitro
CCG-203971 inhibits expression of connective tissue growth factor (CTGF), α-smooth muscle actin (α-SMA), and collagen 1 (COL1A2) in both SSc fibroblasts and in lysophosphatidic acid (LPA)-and transforming growth factor β (TGFβ)-stimulated fibroblasts.
In vivo
CCG-203971 exhibits promising anti-fibrotic activity both in vitro and in vivo in several animal models of disease, including intestinal fibrosis, pulmonary fibrosis and dermal fibrosis. The half-life of this compound in mouse liver microsomes (MLM) is only 1.6 min, indicating high susceptibility to oxidative metabolism. In vivo treatment with this compound also preventes bleomycin-induced skin thickening and collagen deposition.
Human dermal fibroblasts (2.0 × 104) are plated into a 96-well plate and grown overnight in DMEM containing 10% FBS. Media are removed and replaced with DMEM containing 2% FBS and 30 μM CCG-203971 or 0.1% DMSO control. After 72 hours WST-1 dye is added to each well, and after 60 minutes absorbance at 490 nm was read.
POLITIQUE DE RETOUR
La politique de retour inconditionnelle de Selleck Chemical garantit une expérience d'achat en ligne fluide à nos clients. Si vous n'êtes en aucun cas satisfait de votre achat, vous pouvez retourner tout article dans les 7 jours suivant sa réception. En cas de problèmes de qualité du produit, qu'il s'agisse de problèmes liés au protocole ou au produit, vous pouvez retourner tout article dans les 365 jours suivant la date d'achat initiale. Veuillez suivre les instructions ci-dessous lors du retour des produits.
EXPÉDITION ET STOCKAGE
Les produits Selleck sont transportés à température ambiante. Si vous recevez le produit à température ambiante, soyez assuré que le service d'inspection de la qualité de Selleck a mené des expériences pour vérifier que le placement à température normale pendant un mois n'affectera pas l'activité biologique des produits en poudre. Après réception, veuillez stocker le produit conformément aux exigences décrites dans la fiche technique. La plupart des produits Selleck sont stables dans les conditions recommandées.
NON DESTINÉ À UN USAGE HUMAIN, VÉTÉRINAIRE DIAGNOSTIQUE OU THÉRAPEUTIQUE.