Y-39983 Dihydrochloride

N° de catalogueS7935 Lot :S793504

Imprimer

Données techniques

Formule

C16H16N4O.2HCl

Poids moléculaire 353.25 Numéro CAS 173897-44-4
Solubilité (25°C)* In vitro DMSO 70 mg/mL (198.15 mM)
Water 70 mg/mL (198.15 mM)
Ethanol 2 mg/mL (5.66 mM)
In vivo (Ajouter les solvants au produit individuellement et dans lordre.)
Homogeneous suspension
CMC-NA
≥5mg/ml Taking the 1 mL working solution as an example, add 5 mg of this product to 1 ml of CMC-Na solution, mix evenly to obtain a homogeneous suspension with a final concentration of 5 mg/ml.
Clear solution
5%DMSO 40%PEG300 5%Tween80 50%ddH2O

Validé par les laboratoires Selleck. Si vous avez besoin dajustements à cette formulation, contactez notre équipe commerciale pour des tests personnalisés.

3.550mg/ml (10.05mM) Taking the 1 mL working solution as an example, add 50 μL of 71 mg/ml clarified DMSO stock solution to 400 μL of PEG300, mix evenly to clarify it; add 50 μL of Tween80 to the above system, mix evenly to clarify; then continue to add 500 μL of ddH2O to adjust the volume to 1 mL. The mixed solution should be used immediately for optimal results. 
Clear solution
5% DMSO 95% Corn oil

Validé par les laboratoires Selleck. Si vous avez besoin dajustements à cette formulation, contactez notre équipe commerciale pour des tests personnalisés.

0.580mg/ml (1.64mM) Taking the 1 mL working solution as an example, add 50 μL of 11.6 mg/ml clear DMSO stock solution to 950 μL of corn oil and mix evenly. The mixed solution should be used immediately for optimal results. 
* <1 mg/ml signifie légèrement soluble ou insoluble.
* Veuillez noter que Selleck teste la solubilité de tous les composés en interne, et la solubilité réelle peut différer légèrement des valeurs publiées. Ceci est normal et est dû à de légères variations dun lot à lautre.
* Expédition à température ambiante (les tests de stabilité montrent que ce produit peut être expédié sans aucune mesure de refroidissement.)

Préparation des solutions mères

Activité biologique

Description Y-39983 (Y-33075)Dihydrochloride est un inhibiteur sélectif de la rho-associated protein kinase(ROCK) avec une IC50 de 3,6 nM.
Cibles
ROCK
(Cell-free assay)
3.6 nM
In vitro

Y-39983 s'oppose à la phosphorylation de MYPT1 dépendante de ROCK, principalement au niveau de la Thr853, avec une diminution correspondante de la phosphorylation de MLC. Il réduit la phosphorylation aux niveaux de la Thr696 et de la Thr853 et entraîne une contraction réduite de l'actomyosine. Y-39983 présente une IC50 d'environ 200 nM pour la déphosphorylation à la Thr696 et de seulement 15 nM pour la déphosphorylation à la Thr853. L'IC50 pour la déphosphorylation de MLC est de 14 nM.

In vivo

Y-39983 supprime significativement les symptômes cliniques de l'EAE et prévient sa rechute tout en augmentant la quantité de protéines myéliniques. Son traitement entraîne une démyélinisation réduite sans changement significatif des dommages axonaux, ce qui peut être dû à l'inactivation des substrats de ROCK, y compris la (p)-MLC phosphorylée, LIMK2 et CRMP-2, qui sont importants pour la croissance des neurites, l'effondrement des cônes de croissance et la remyélinisation des oligodendrocytes.

Protocole (de référence)

Test cellulaire :

[3]

  • Lignées cellulaires

    Human glaucomatous trabecular meshwork (GTM3) cell line

  • Concentrations

    5 μM

  • Temps dincubation

    1 h

  • Méthode

    Cell cultures of an immortalized human glaucomatous trabecular meshwork (GTM3) cell line are grown at 37℃ in 5% CO2 in Dulbecco's Minimum Essential Medium (DMEM + Glutamax) . Upon reaching confluence, cells are divided using 0.05% trypsin. Cells of passages 13 to 20 are used in experiments. Cells are treated with 5 μM of the specific ROCK inhibitors, Y-27632 and Y-39983, for 1 h in a serum-rich medium. Cell lysate is used for western blotting to test effect of ROCK inhibitors on the phosphorylation of MYPT1 and MLC.

Étude animale :

[2]

  • Modèles animaux

    SJL/J mice

  • Posologies

    100 μl of 10 μM

  • Administration

    i.p.

Références

  • https://pubmed.ncbi.nlm.nih.gov/26486225/
  • https://pubmed.ncbi.nlm.nih.gov/24008512/
  • https://pubmed.ncbi.nlm.nih.gov/21850162/

Sellecks Y-39983 Dihydrochloride A été cité par 6 Publications

A highly efficient, scalable pipeline for fixed feature extraction from large-scale high-content imaging screens [ iScience, 2024, 27(12):111434] PubMed: 39720532
A multiparametric screen uncovers FDA-approved small molecules that potentiate the nuclear mechano-dysfunctions in ATR-defective cells [ Sci Rep, 2024, 14(1):30786] PubMed: 39730498
Effects of Rho-Associated Kinase (Rock) Inhibitors (Alternative to Y-27632) on Primary Human Corneal Endothelial Cells [ Cells, 2023, 12(9)1307] PubMed: 37174707
The Global Phosphorylation Landscape of SARS-CoV-2 Infection [ Cell, 2020, 182(3):685-712.e19] PubMed: 32645325
Simulated microgravity inhibits the viability and migration of glioma via FAK/RhoA/Rock and FAK/Nek2 signaling. [ In Vitro Cell Dev Biol Anim, 2019, 55(4):260-271] PubMed: 30820814
Phosphorylation of ARHGAP19 by CDK1 and ROCK regulates its subcellular localization and function during mitosis. [ J Cell Sci, 2018, 131(5)] PubMed: 29420299

POLITIQUE DE RETOUR
La politique de retour inconditionnelle de Selleck Chemical garantit une expérience dachat en ligne fluide à nos clients. Si vous nêtes en aucun cas satisfait de votre achat, vous pouvez retourner tout article dans les 7 jours suivant sa réception. En cas de problèmes de qualité du produit, quil sagisse de problèmes liés au protocole ou au produit, vous pouvez retourner tout article dans les 365 jours suivant la date dachat initiale. Veuillez suivre les instructions ci-dessous lors du retour des produits.

EXPÉDITION ET STOCKAGE
Les produits Selleck sont transportés à température ambiante. Si vous recevez le produit à température ambiante, soyez assuré que le service dinspection de la qualité de Selleck a mené des expériences pour vérifier que le placement à température normale pendant un mois naffectera pas lactivité biologique des produits en poudre. Après réception, veuillez stocker le produit conformément aux exigences décrites dans la fiche technique. La plupart des produits Selleck sont stables dans les conditions recommandées.

NON DESTINÉ À UN USAGE HUMAIN, VÉTÉRINAIRE DIAGNOSTIQUE OU THÉRAPEUTIQUE.